Posts Tagged ‘a/c repair atlanta’

Free Freon? Is it really free?

Friday, April 16th, 2010

Free service call. Free diagnostic with service call. Free repair with paid service call. Free furnace with air conditioner!! And now FREE FREON. I know you have seen them all before. That ad that screams an offer that is too good to be true. It makes you stop just a second and ask yourself, could this really be free- like that quarter laying on the ground of the parking lot- or is just a come on to get me to buy something else at an inflated price to cover the cost of the “free” offering?
I have always found there is no “free” in life, that free always comes with strings attached and sometimes those strings are not pleasant. The free service call, the free repair, the free furnace and free diagnostic are all priced into what you are charged for and in the end you pay more for usually inferior goods and services than if you had just used an honest contractor offering no free services.

Now comes the most harmful “free promotion” I have seen used as a marketing campaign to date: The offering of “free Freon” if your unit has a leak and needs a recharge of refrigerant. While this is a way to get in the home and pitch a new system to the homeowner with a leaky system which needs to be replaced, the danger of this advertising campaign is there will be people who have systems that leak thousands of pounds of Freon into the atmosphere every summer and they will take advantage of this program to simply put more Freon in their system only to have it leak out two or three times over the season. The problem with this is that Freon, which is just a brand name for R-22 refrigerant is actually difluoromonochloromethane which is a hydrochloroflurocarbon or HCFC, a poisonous toxic gas that when released into the atmosphere causes damage to the environment and the ozone layer. It is not something to be pumped into leaking systems to only leak out into the atmosphere. If you have a leaking air conditioning system, the proper course of action is the stop the leak and stop polluting the world for future generations.

If you call this company, they will gladly come out and pump your system full of difluoromonochloromethane at no charge and keeping coming back and filling it up at no charge as it leaches into the air we breathe. This is just not being socially conscious or “green”. They may think it is a good way to get into your home to try and sell you a new system, but in the real world, a lot of people will just opt to have their systems filled up over and over again, never really knowing what problem they are contributing to. A law was passed called the Clean Air Act and it called for the removal of Freon from our cars first then our homes and businesses. It is now illegal to keep pumping up a leaky air conditioner that has over 50 pounds of Freon in it and it is environmentally irresponsible to keep pumping up a home air conditioning system that will just contribute to a problem that will have long reaching ramifications for future generations.

I seriously doubt the company advertising this “free freon” promotion meant any harm. They are by all accounts an honest company that does good work. The heating & cooling industry is extremely competitive in the Atlanta area and we’re all looking for new and inventive ways to grow our businesses, but we have to make sure that we do it in an ethical and environmentally responsible manner.

The bottom line is this: Do not be fooled into thinking you are getting something for nothing. Repair or Replace your leaky air conditioner instead of just pumping it up. I still believe what my parents taught me years ago: Nothing free is worth having.

AHRI news release 09/23/2009

Wednesday, September 23rd, 2009

For Immediate Release Contact: Colleen Hughes, AHRI Public Affairs
Direct: 703.600-0331
(excerpts)
Homeowners Urged to Replace Storm Damaged Heating and Cooling Equipment
Arlington, VA (June 12, 2008) — After a flood or hurricane, homeowners are advised to take important safety precautions with regard to their home’s heating and cooling systems, according to the Air-Conditioning, Heating, and Refrigeration Institute (AHRI), the trade association representing manufacturers of this equipment.
“A house or basement exposed to standing water can damage a home’s heating and cooling equipment — putting families at risk,” said AHRI President Stephen Yurek. “We advise homeowners to play it safe and replace, rather than repair flood-damaged heating and cooling equipment and systems.”
AHRI recommends that all inspection and replacement work on flooded equipment be performed by qualified heating and cooling contractors, not by homeowners.

“Homeowners can turn misfortune into opportunity by considering new, energy-efficient models that will lower their future energy bills,” said Yurek. “They also should ask their local utility about available rebates for installing new, energy-efficient heating and cooling equipment.”
Gas Furnaces and Boilers If there is any question whether flood water has reached a gas furnace or boiler, it should be checked by a qualified contractor. This equipment gas valves and controls that are especially vulnerable to water damage from floods — damage that might not be visible. Corrosion begins inside the valves and controls, and damage may not be apparent, even if the outside of the device is clean and dry. At a minimum, this damage can result in reliability problems.
Electric Furnaces An electric furnace consists of electrically heated coils, a fan to provide air circulation across the coils, and controls that include safety relays. As with a gas furnace, an electric furnace is susceptible to corrosion and damage from flood water, creating potential reliability problems or safety hazards. If there is any question whether flood water has reached an electric furnace, homeowners should have it checked by a contractor.
Propane Heating
Use extreme caution where there is the potential for propane leaks and have propane equipment checked, repaired and/or replaced by a contractor as quickly as possible after a flood. In every case, contractors must replace all valves and controls that have been in contact with flood water. The gas pressure regulator on a propane system should also be checked. This regulator contains a small vent hole to sense outside pressure. For effective gas pressure regulation, this hole must always remain unobstructed. During a flood, debris can easily plug the hole, causing dangerous malfunction or corrosion.

AHRI News Release Page 2

Radiant Ceiling Heat With this type of heating system, electrically-heated cables are embedded in the plaster or drywall ceiling. The cables warm the ceiling, which in turn warms the room by radiant heat. If the ceiling becomes wet from a flood, it can weaken and perhaps crack and the ceiling will need replacement. Although the electrical cables themselves may appear to be undamaged due to their tough, waterproof coating, there may have been large mechanical stresses on the cable, and a qualified electrician should be consulted to determine whether the cable can continue to be used.
Heat Pumps and Air Conditioning Systems Split air conditioning and heat pump systems have power and control wiring between the indoor and outdoor parts of the system, and piping through which refrigerant flows through the system. If flood water has repositioned either the indoor or outdoor units of a split system even by a small amount, there is a potential for refrigerant leaks. The system will then require major repair or full replacement.
If the refrigerant system remains intact after the flood, the entire system should be cleaned, dried and disinfected. Homeowners should have a contractor check the indoor and outdoor units’ electrical and refrigeration connections, including all control circuits. The decision to repair or replace should be made after consultation with a qualified professional on a case-by-case basis.
Ductwork If a house under storm repair contains a central forced-air system, attention should also be paid to the ductwork. A contractor will not try to salvage duct insulation that has been in contact with flood water, but will replace it because it is impossible to decontaminate. The contractor also will clean, dry and disinfect the ductwork itself. A thorough job will require disassembling the ductwork, but the silver lining is that such repairs will allow the contractor to seal joints in the ductwork and improve insulation to reduce heat and cooling loss.
Water Heating Systems Whether a water heater uses gas, oil or electricity, and it was exposed to flood water, the unit should be replaced. A new water heater is a relatively small investment, and replacing it is fairly easy to do. If the water heater was more than five years old, chances are a new unit will be more efficient, saving the homeowner money in the long run.
In a gas unit, valves and controls can corrode. In an electric unit, the thermostat and controls can corrode. In both types, the insulation surrounding the unit will likely be contaminated and will be nearly impossible to disinfect. In addition, the insulation takes a great deal of time to dry and can lead to corrosion of the tank from the outside.
Even if water heater components have been cleaned and the unit seems to operate properly, parts may corrode in the future. Both gas and electric water heaters have a pressure relief valve that can corrode and stick after being exposed to flood water. Homeowners should be sure, therefore, to replace this valve as well.
Government Aid For victims of some natural disasters, government aid may be available to help consumers finance the replacement of flood-damaged HVAC equipment. Homeowners should contact any of the offices set up by the Federal Emergency Management Agency (FEMA) to help flood victims in their area.
The Air-Conditioning, Heating, and Refrigeration Institute is the trade association representing manufacturers of air conditioning, heating and commercial refrigeration equipment. An internationally recognized advocate for the industry, AHRI develops standards for and certifies the performance of many of these products. AHRI’s more than 350 member companies account for more than 90 percent of the residential and commercial air conditioning, space heating, water heating and commercial refrigeration equipment manufactured and sold in North America.

What the heck is Puron (R410a) anyway?

Thursday, January 22nd, 2009

by DAN JAPE of RELIABLE HEATING & AIR originally published June 2008.

Freon or Puron? That is the question. Whether is nobler to protect the ozone layer or your pocketbook. Now is the time to consider that change has arrived. As many people are aware, Freon or R-22 is on the way , outlawed by government mandate to be discontinued in home air conditioners by the end of 2009. Starting January 1, 2010, all cooling units produced and sold will no longer be able to use R-22 Freon, the old refrigerant long favored in air conditioning. Starting January, 1 2015, there is a ban on sale and use of all R-22 except for certain uses and by that time the EPA predicts a 90% phase out of R-22. And then on January 1, 2020, all Freon R-22 will be gone except for old, recycled stockpiles of used refrigerant.

This time deadline has seemed like it is far away, but it is now right around the corner and if you buy a new Freon based air conditioner today, you may be in for a surprise tomorrow. Freon is going to shoot up in price, quickly and by the time your new air conditioner is in need of service, it will be more expensive that purchasing a new unit that runs on R410a or Puron, as the new alternative refrigerant is called.

The good news here is that R410a is a far better refrigerant than Freon R-22 ever was. It cools better, dehumidifies better, and is more efficient than R-22. R410a provides a much colder air coming out of your vents, dropping the temperature of the air 25 to 28 degrees each time it passes over your cooling coil. You will also find it does a much better job of removing the humidity in the air, which is half the battle in Metro Atlanta. There are many wonderful things about this new refrigerant, but the most important thing is that this is the only alternative on the market for cooling your home.

Many air conditioning companies have refused to invest in the new equipment needed to service and install this new refrigerant, instead telling the customer nothing about it, or misleading them about the truth on the subject. Just yesterday, I had a potential customer tell me that out of five companies he had bid his new system, two told him nothing about this upcoming phase-out and two told him it was “no big deal” and Freon R-22 would be around for many years and plentiful. The truth is, many of the lower priced air conditioner manufactures have built a lot of R-22 units, thinking the lower price would sell these outdated units and now they have to dump them on an unsuspecting consumer.

The truth about this phase out is just a Google away and no one should ignore it, regardless of what any dealer tells you. The government decided long ago to use a long, gradual phase out of Freon as the smartest way to deal with this issue. Do not wait until the very end to look into it. R410a is only slightly more expensive today and if your heating and air conditioning company does not mention it, or offer it, look elsewhere quickly and do not be mislead. The time is here now to make the change, and in the future, you will very glad you did.